Overview
The Manitowoc Indigo NXT R290 ice machine is displaying error code E10 (Flooding Evaporator 2).
Primary Cause
Dual circuit TXV stuck open or sensing bulb detached
Recommended Technical Fix
Secure sensing bulb to suction line and verify circuit pressures.