Manitowoc Indigo NXT R290 Error Code E10: Flooding Evaporator 2

Overview

The Manitowoc Indigo NXT R290 ice machine is displaying error code E10 (Flooding Evaporator 2).

Primary Cause

Dual circuit TXV stuck open or sensing bulb detached

Recommended Technical Fix

Secure sensing bulb to suction line and verify circuit pressures.