Overview
The Manitowoc Indigo NXT R290 ice machine is displaying error code E09 (Flooding Evaporator 1).
Primary Cause
Refrigerant overcharge or TXV stuck open
Recommended Technical Fix
Inspect TXV bulb mounting and check refrigeration circuit superheat.