Overview
The Manitowoc Indigo NXT R290 ice machine is displaying error code E12 (Curtain Switch Fault).
Primary Cause
Water curtain stuck open or magnetic switch open > 24 hours
Recommended Technical Fix
Inspect curtain movement
The Manitowoc Indigo NXT R290 ice machine is displaying error code E12 (Curtain Switch Fault).
Water curtain stuck open or magnetic switch open > 24 hours
Inspect curtain movement